The effect of different curing distances on the microhardness of flowable bulk-fill composite materials

Main Article Content

Ayah A Alzaidy
https://orcid.org/0000-0001-6086-065X
Manal H Abd-alla
https://orcid.org/0000-0001-7732-7376

Abstract

Background: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For each material, three subgroups were fabricated according to the position of the light curing tip from the top surface; at 0, 2, and 4 mm distances. Microhardness was measured using the Vickers test with a 50-g load for 15 seconds for the top and bottom surfaces of all the samples. Results: The microhardness values were decreased in the following order; 0mm > 2mm > 4mm curing tip distance, for both sides and Tetric N had the highest microhardness values. Significant differences in microhardness were recorded between the top and bottom surfaces for all the specimens (p<0.05). Conclusion: Increasing the distances between the tip of the light cure and the surface of flowable bulk-fill resins can significantly decrease the microhardness of the bottom surfaces compared to the top surfaces.

Downloads

Download data is not yet available.

Article Details

Section

Research Articles

Author Biographies

Ayah A Alzaidy , Department of conservative dentistry, College of Dentistry, Mustansiriyah University, Iraq

Department of conservative dentistry, College of Dentistry, Mustansiriyah University, Iraq

Manal H Abd-alla , Department of conservative dentistry, College of Dentistry, Mustansiriyah University, Iraq

Department of conservative dentistry, College of Dentistry, Mustansiriyah University, Iraq

How to Cite

1.
Alzaidy AA, Abd-alla MH. The effect of different curing distances on the microhardness of flowable bulk-fill composite materials. J Bagh Coll Dent [Internet]. 2023 Dec. 15 [cited 2024 Dec. 24];35(4):20-7. Available from: https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/3507

References

AnandYokesh CA, Hemalatha P, Muthalagu M, Robert Justin M. Comparative evaluation of the depth of cure and degree of conversion of two bulk fill flowable composites. J Clin Diagnostic Res. 2017; 11(8): 86-89.

Sousa-lima RX, Margarida A, Karine L, Guimarães C, Othávio R, Assunção D. Mechanical properties of low and regular viscosity bulk fill composites in a 3D dentin cavity model fill composites in a 3D dentin cavity model. J Adhes Sci Technol. 2020; 35(3), 325-335.

Aung SZ, Takagaki T, Ikeda M, Nozaki K, Burrow MF, Abdou A, et al. The effect of different light curing units on vickers microhardness and degree of conversion of flowable resin composites. Dent Mater J. 2021; 40(1): 44-51.

Comba A, Scotti N, Maravić T, Mazzoni A, Carossa M, Breschi L, Cadenaro M. Vickers hardness and shrinkage stress evaluation of low and high viscosity bulk-fill resin composite. Polymers. 2020; 12(7): 1-12.

Malik and Baban LM. The effect of light curing tip distance on the curing depth of bulk fill resin based composites. J Baghdad Coll Dent. 2014; 26(4): 46-53.

Taheri A, Ikhar A, Nikhade P, Tawani G, Patel A, Ali Z. Comparative evaluation of fracture resistance of endodontically treated premolars with one remaining cavity wall restored using different techniques and materials: An in vitro study. Saudi Endod J. 2021; 11(1):36-41.

Beolchi RS, Moura-Netto C, Palo RM, Torres CR, Pelissier B. Changes in irradiance and energy density in relation to different curing distances. Braz Oral Res. 2015; 29(1): 1-7.

Aguiar FHB, Lazzari CR, Lima DANL, Ambrosano GMB, Lovadino JR, Effect of light curing tip distance and resin shade on microhardness of a hybrid resin composite. Braz Oral Res. 2005; 19(4): 302-306.

Pirmoradian M., Hooshmand T., Jafari-Semnani S., Fadavi F. Degree of conversion and microhardness of bulk-fill dental composites polymerised by LED and QTH light curing units. J Oral Biosci. 2020; 62(1): 107-113.

Tarle Z, Attin T, Marovic D, Andermatt L, Ristic M, Tauböck T. Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites. Clin Oral Investig. 2015; 19.4: 831-840.

Diab RA, Yap AU, Gonzalez MAG, Yahya NA. Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites. Saudi Dent J. 2021; 33(8): 1184-1189.

Ilie N, Keßler A, Durner J. Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulkfill resin based composites. J Dent. 2013; 41(8): 695-702.

Haugen HJ, Marovic D, Par M, Le Thieu MK, Reseland JE, Johnsen GF. Bulk fill composites have similar performance to conventional dental composites. Int J Mol Sci. 2020; 21(14):1-20.

Jafarzadeh TS, Erfan M, Behroozibakhsh M, Fatemi M, Masaeli R, Rezaei Y, et al. Evaluation of Polymerization Efficacy in Composite Resins via FT-IR Spectroscopy and Vickers Microhardness Test. J Dent Res Dent Clin Dent Prospect.. 2015; 9(4): 226-232.

Bagnato V, Galvão M, Caldas S, Rastelli A, Andrade M. Evaluation of degree of conversion and hardness of dental composites photoactivated with different light guide tips. Eur J of Dent. 2013; 7: 86-93.

Yap AUJ., Wong NY., Siow KS., Composite cure and shrinkage associated with high intensity curing light. Oper Dent. 2003; 28: 357-364.

Nogueira J., Borsatto M., Souza-Zaroni W., Ramos R., Palma-Dibb R., Microhardness of composite resins at different depths varying the post-irradiation time. J Appl Oral Sci. 2007; 15(4): 305-309.

Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Invest.2014; 18(8) :1991-2000.

Thomé T, Steagall W, Jr., Tachibana A, Braga SR, Turbino ML. Influence of the distance of the curing light source and composite shade on hardness of two composites. J Appl Oral Sci. 2007;15(6): 486-491.

Kelić K, Matić S, Marovic D, Klarić E, Tarle Z. Microhardness of Bulk-Fill Composite Materials. Acta Clin Croat. 2016; 55:607-614.

Oja J, Lassila L, Vallittu PK, Garoushi S. Effect of Accelerated Aging on Some Mechanical Properties and Wear of Different Commercial Dental Resin Composites. Mater. 2021; 14(11): 2769.

Yu P, Yap AUJ, Wang XY. Degree of conversion and polymerisation shrinkage of bulk-fill resin-based composites. Oper Dent. 2017; 42(1):82-89.

Galvão MR, Caldas SGFR, Bagnato VS, de Souza Rastelli AN, de Andrade MF. Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips. Eur J Dent. 2013; 7(1):86-93.

Silva FF, Mendes LC, Ferreira M, Benzi MR. Degree of conversion versus the depth of polymerization of an organically modified ceramic dental restoration composite by Fourier transform infrared spectroscopy. J Appl Polym Sci. 2007; 104(1), 325-330.

Tsuzuki FM, Castro-Hoshino LV de, Lopes LCP, Sato F, Baesso ML, Terada RSS. Evaluation of the influence of light-curing units on the degree of conversion in depth of a bulk-fill resin. J Clin Exp Dent. 2020;12(12):117-123.

Bahbishi N, Mzain W, Badeeb B, Nassar H. Color Stability and Micro-Hardness of Bulk-Fill Composite Materials after Exposure to Common Beverages. Materials. 2020; 13(3):787.

Sunbul HA, Silikas N, Watts DC. Surface and bulk properties of dental resin- composites after solvent storage. Dent Mater. 2016; 32:987-997.

Similar Articles

You may also start an advanced similarity search for this article.