Background: To evaluate the ISO depth of cure of bulkfill composites and depth of cure which determined by Vickers microhardness test.
Materials and Methods: Bulkfill resin composite specimens (n=150) were prepared of three bulkfill composite materials (TetricEvo Ceram, Quixfil and SDR) and light cured by Flash max p3 for 3, 10, 20 seconds and by wood pecker for 10, 20 seconds respectively, a mold was filled with one of the three bulkfill composites and light cured. The specimens removed from the mold and scraped by plastic spatula and the remaining length (absolute length) was measured which represent the ISO depth of cure. After that the specimens were returned into the mold and a microhardness indentation device applied on the specimen and hardness measurements (Vickers hardness, VHN) were made at defined distance, beginning at the resin composite that had been closest to the light curing unit (i.e. at the top) and proceeding toward the uncured resin composite (i.e. toward the bottom) on the basis of the VHN measurement, Vickers hardness test generated for each group.
Results and Conclusion: ISO depth of cure of bulkfill composite materials is time and type of light curing protocol dependent rather than type of material of bulkfill composite while the depth of cure determined by Vickers hardness number is material dependent in addition to the light curing protocol.
Key words: Bulkfill composite light curing intensity, depth of cure.

Downloads

Download data is not yet available.

Article Details

Section

Restorative Dentistry

How to Cite

1.
A MR, Baban LM. The Effect of LED Light on Depth of Cure and Microhardness of Three Types of Bulkfill Composite. J Bagh Coll Dent [Internet]. 2016 Mar. 15 [cited 2024 Dec. 22];28(1):36-40. Available from: https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/1081