Evaluation of plane-line matching of three-dimensional cephalometric analysis using artificial intelligence assisted software
Main Article Content
Abstract
The introduction of three-dimensional technology has revolutionized the orthodontic digital workflow and facilitated diagnosis and treatment planning. The aims of this study were to evaluate the plane-line matching of conventional lateral cephalometric analysis and three dimensional cone beam computed tomography (CBCT) and to assess the reliability and consistency of linear and angular measurements obtained from the two digital modality. Materials and Methods: Forty five participants with an age range of 18-26 years and Class I skeletal malocclusion were recruited. A standardized cephalometric radiograph and CBCT scans were obtained according to specific indication protocols. The digital images were analyzed using an AI based software, 3D Slicer (version 5.6.2), for enhancement and registration. Anatomical landmarks were allocated and anatomical planes and lines, were aligned for quantitative measurements analysis. Results: The findings indicated an acceptable degree of matching between the two-dimensional cephalometric X-ray analysis and the three-dimensional CBCT analysis. Although linear measurements showed high consistency, some angular measurements presented statistically significant differences between the two modalities. Overall, the paired t-test results indicated that certain measurements, such as ANS-Me and N-Me, exhibited variability, while others, like SN and NB, showed no significant differences. The reliability of measurements was further confirmed using the Intraclass Correlation Coefficient (ICC), which demonstrated strong consistency across most linear measurements. Conclusion: The study concluded that three-dimensional cephalometric analysis using CBCT provides a promising approach for comprehensive and accurate assessment of craniofacial structures, offering significant advantages over traditional two-dimensional methods.
Received date: 02-03-2025
Accepted date: 04-05-2025
Published date: 15-12-2025
Downloads
Article Details
Issue
Section

This work is licensed under a Creative Commons Attribution 4.0 International License.
Licenses and Copyright
The following policy applies in The Journal of Baghdad College of Dentistry (JBCD):
# JBCD applies the Creative Commons Attribution (CC BY) license to articles and other works we publish. If you submit your paper for publication by JBCD, you agree to have the CC BY license applied to your work. Under this Open Access license, you as the author agree that anyone can reuse your article in whole or part for any purpose, for free, even for commercial purposes. Anyone may copy, distribute, or reuse the content as long as the author and original source are properly cited. This facilitates freedom in re-use and also ensures that JBCD content can be mined without barriers for the needs of research.
# If your manuscript contains content such as photos, images, figures, tables, audio files, videos, etc., that you or your co-authors do not own, we will require you to provide us with proof that the owner of that content (a) has given you written permission to use it, and (b) has approved of the CC BY license being applied to their content. We provide a form you can use to ask for and obtain permission from the owner. If you do not have owner permission, we will ask you to remove that content and/or replace it with other content that you own or have such permission to use.Don't assume that you can use any content you find on the Internet, or that the content is fair game just because it isn't clear who the owner is or what license applies.
# Many authors assume that if they previously published a paper through another publisher, they own the rights to that content and they can freely use that content in their paper, but that’s not necessarily the case, it depends on the license that covers the other paper. Some publishers allow free and unrestricted re-use of article content they own, such as under the CC BY license. Other publishers use licenses that allow re-use only if the same license is applied by the person or publisher re-using the content. If the paper was published under a CC BY license or another license that allows free and unrestricted use, you may use the content in your JBCD paper provided that you give proper attribution, as explained above.If the content was published under a more restrictive license, you must ascertain what rights you have under that license. At a minimum, review the license to make sure you can use the content. Contact that JBCD if you have any questions about the license. If the license does not permit you to use the content in a paper that will be covered by an unrestricted license, you must obtain written permission from the publisher to use the content in your JBCD paper. Please do not include any content in your JBCD paper which you do not have rights to use, and always give proper attribution.
# If any relevant accompanying data is submitted to repositories with stated licensing policies, the policies should not be more restrictive than CC BY.
# JBCD reserves the right to remove any photos, captures, images, figures, tables, illustrations, audio and video files, and the like, from any paper, whether before or after publication, if we have reason to believe that the content was included in your paper without permission from the owner of the content.
How to Cite
References
Singh D. Cone-beam Computed Tomography: A New Era in Clinical Orthodontics. Inter J Health Sci 2021:411-27.
Dai F, Chen S, Feng T, Lu W, Chen G, Jiang J, et al. Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study. Odontol. 2023;111(1):238-47.
Durão AR, Bolstad N, Pittayapat P, Lambrichts I, Ferreira AP, Jacobs R. Accuracy and reliability of 2D cephalometric analysis in orthodontics. Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial. 2014;55(3):135-41.
Li C, Teixeira H, Tanna N, Zheng Z, Chen SHY, Zou M, et al. The reliability of two-and three-dimensional cephalometric measurements: A CBCT study. Diagnostics. 2021;11(12):2292.
Al-Ubaydi AS, Al-Groosh D. The validity and reliability of automatic tooth segmentation generated using artificial intelligence. Sci World J. 2023;2023(1):5933003.
Ali SMAE, Elkhateeb SM. Validity of CBCT for Soft Tissue Examination in the Maxillofacial Area: A Review of the Current Literature. ASDJ. 2024;35(3):134-148.
Al-Ubaydi AS, Al-Groosh D. Do the Various Indirect Bonding Techniques Provide the Same Accuracy for Orthodontic Bracket Placement? (Randomized Clinical Trial). International J Dent. 2024;2024:5455197.
Lo L-J, Lin H-H. Applications of three-dimensional imaging techniques in craniomaxillofacial surgery: A literature review. biomed J. 2023:100615.
Gupta A. On imaging modalities for cephalometric analysis: a review. Multimedia Tools and Applications. 2023;82(24):36837-58.
Abdaljawwad AA, Al-Groosh DH. Effects of various analgesics on pain perception and rate of tooth movement: a randomized controlled clinical study. J Bagh Coll Dent. 2022;34(2):37-51.
Rozylo-Kalinowska I, Cephalometric Radiograph in Dentistry/Oral Health. In: Imaging Techniques in Dental Radiology. Springer, Cham. 2020:57-64.
Wan Y, Chen Q, Lei X, Wang Y, Chen Y, Hu H, et al. A Calibration Method of CBCT Geometric Parameters Based on the Visual Imaging Model. Advances in Natural Computation, Fuzzy Systems and Knowledge Discovery: 2020; (2). Springer.
Hassan NA, Al-Jaboori ASK, Al-Radha ASD, Ali MQ, Albayati RM. CBCT Analysis of Edentulous Mandibular Symphysis in Iraqi Patients for Treatment with Implant-Supported Overdentures. Cross-Sectional Single-Center Study. Clinic Cos Investigat Dent. 2023:79-87.
Yoon SJ, Wang RF, Na HJ, Palomo JM. Normal range of facial asymmetry in spherical coordinates: a CBCT study. Imaging Sci Dent. 2013;43(1):31-36.
Al-Mulla AH, Premjani P, Vaid NR, Fadia DF, Ferguson DJ. Evaluating the accuracy of facial models obtained from volume wrapping: 2D images on CBCT versus 3D on CBCT. Semin Orthod. 2018;24(4):443-450.
Bhuskute KP, Jadhav V, Sharma M, Reche A. Three-dimensional Computer-aided Design System used in Orthodontics and Orthognathic Surgery for Diagnosis and Treatment Planning-A Narrative Review. J Clinic Diagnos Res. 2023;17(11).
Diaz-Pinto A, Alle S, Nath V, Tang Y, Ihsani A, Asad M, et al. Monai label: A framework for ai-assisted interactive labeling of 3d medical images. Med Image Analys. 2024;95:103207.
Klein S, Staring M, Murphy K, Viergever MA, Pluim JP. Elastix: a toolbox for intensity-based medical image registration. IEEE trans med imaging. 2009;29(1):196-205.
Van Griethuysen JJ, Fedorov A, Parmar C, Hosny A, Aucoin N, Narayan V, et al. Computational radiomics system to decode the radiographic phenotype. Cancer res. 2017;77(21):e104-e7.
Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin J-C, Pujol S, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magnetic resonance imaging. 2012;30(9):1323-41.
Ahn J, Nguyen TP, Kim Y-J, Kim T, Yoon J. Automated analysis of three-dimensional CBCT images taken in natural head position that combines facial profile processing and multiple deep-learning models. Comp Meth Prog Biomed. 2022;226:107123.
Proffit WR, Fields H, Larson B, Sarver DM. Contemporary Orthodontics-E-Book: Elsevier Health Sciences; 2018.
IBM Corp N. IBM SPSS statistics for windows. IBM corp Armonk, NY; 2017.
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. International journal of nursing studies. 2010;47(8):931-6.
McGraw KO, Wong SP. Forming inferences about some intraclass correlation coefficients. Psycholo meth. 1996;1(1):30.
Farronato G, Perillo L, Bellincioni F, Briguglio F, Farronato D, Dominici A. Direct 3D cephalometric analysis performed on CBCT. J Inform Tech Soft Engg. 2012;2(107):2.
Kotuła J, Kuc AE, Lis J, Kawala B, Sarul M. New sagittal and vertical cephalometric analysis methods: A systematic review. Diagnostics. 2022;12(7):1723.
Khamees AM, Al-Groosh DH, Al-Rawi NH. Effects of vitamin D deficiency on bone and root resorption post-orthodontic retention in rats. J Bagh Coll Dent. 2023;35(2):54-64.
Baldini B, Cavagnetto D, Baselli G, Sforza C, Tartaglia GM. Cephalometric measurements performed on CBCT and reconstructed lateral cephalograms: a cross-sectional study providing a quantitative approach of differences and bias. BMC Oral Health. 2022;22(1):98.
Durão AR, Alqerban A, Ferreira AP, Jacobs R. Influence of lateral cephalometric radiography in orthodontic diagnosis and treatment planning. The Angle Orthodontist. 2015;85(2):206-10.
Leonardi R, Giordano D, Maiorana F, Spampinato C. Automatic cephalometric analysis: a systematic review. The Angle Orthodontist. 2008;78(1):145-51.
Kazimierczak W, Gawin G, Janiszewska-Olszowska J, Dyszkiewicz-Konwińska M, Nowicki P, Kazimierczak N, et al. Comparison of Three Commercially Available, AI-Driven Cephalometric Analysis Tools in Orthodontics. J Clin Med. 2024;13(13):3733.
Sahlsten J, Järnstedt J, Jaskari J, Naukkarinen H, Mahasantipiya P, Charuakkra A, et al. Deep learning for 3D cephalometric landmarking with heterogeneous multi-center CBCT dataset. PloS one. 2024;19(6):e0305947.
Alessandri-Bonetti A, Sangalli L, Salerno M, Gallenzi P. Reliability of artificial Intelligence-Assisted cephalometric analysis. A Pilot Study. Biomedinformatics. 2023;3(1):44-53.
Darzi F, Bocklitz T. A Review of Medical Image Registration for Different Modalities. Bioengineering. 2024;11(8):786.
Unberath M, Gao C, Hu Y, Judish M, Taylor RH, Armand M, et al. The impact of machine learning on 2d/3d registration for image-guided interventions: A systematic review and perspective. Frontiers in Robotics and AI. 2021;8:716007.
Pinto-Coelho L. How artificial intelligence is shaping medical imaging technology: A survey of innovations and applications. Bioengineering. 2023;10(12):1435.
Stamatakis HC, Steegman R, Dusseldorp J, Ren Y. Head positioning in a cone beam computed tomography unit and the effect on accuracy of the three‐dimensional surface mode. European J oral Sci. 2019;127(1):72-80.
Olszewski R, Tanesy O, Cosnard G, Zech F, Reychler H. Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses. J Cranio-Maxillo Surg. 2010;38(3):214-21.
Muenzing SE, van Ginneken B, Murphy K, Pluim JP. Supervised quality assessment of medical image registration: Application to intra-patient CT lung registration. Medical image analysis. 2012;16(8):1521-31.
Malkoc S, Sari Z, Usumez S, Koyuturk AE. The effect of head rotation on cephalometric radiographs. The European J Ortho. 2005;27(3):315-21.
Mahmood RR, Jassim IS, Yassir YA. Influential Effect of Digital Smile Design on Orthodontic Treatment Decision. Sci J Med Res. 2022;6(22):1-5.
Raz E, Nossek E, Sahlein DH, Sharashidze V, Narayan V, Ali A, et al. Principles, techniques and applications of high resolution cone beam CT angiography in the neuroangio suite. J Neurointerven Sur. 2023;15(6):600-7.
Dagan M, Kolben Y, Goldstein N, Ben Ishay A, Fons M, Merin R, et al. Advanced hemodynamic monitoring allows recognition of early response patterns to diuresis in congestive heart failure patients. J Clin Med. 2022;12(1):45.
Millett DT, Benson PE, Cunningham SJ, McIntyre GT, Fleming PS, Naini FB, et al. Systematic reviews in orthodontics: a fresh look to promote renewal and reduce redundancy. American J Ortho Dentofaci Orthoped. 2022;162(1):1-2.
Xiang B, Lu J, Yu J. Evaluating Tooth Segmentation Accuracy and Time Efficiency in CBCT Images using Artificial Intelligence: A Systematic Review and Meta-analysis. J Dent. 2024:105064.