Crystallization firing effect on the marginal discrepancy of the IPS. emax CAD crowns using two different CAD/CAM systems

Main Article Content

Fatima K Ghadeer
https://orcid.org/0000-0002-1398-5713
Lateef E Alwan
https://orcid.org/0000-0001-5870-2628
Abdul Kareem J Al-Azzawi

Abstract

Background: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two subgroups pre-crystallized (Group A1, B1) and crystallized crowns (Group A2, B2). At four points on each aspect of the crown, marginal gaps were assessed on the master metal die by using digital microscope at a magnification of (110X) and image- J program. The measurement was done twice for each crown; before and after crystallization process.Results: The lowest mean of marginal gap before and after crystallization was (29.387±2.774μm) and (70.108±5.569μm) respectively for Group A (Imes - Icore system) and the highest mean value before and after crystallization was (51.728 ±3.774μm) and (84.071 ±4.567μm) respectively for Group B (Sirona system). Paired sample t-test result showed a statistically highly significant difference in marginal gap between all groups.Conclusions: The crystallization process increases the vertical marginal gap. Imes - Icore system showed the lower marginal gap than Sirona system. The two systems have an acceptable marginal gap

Downloads

Download data is not yet available.

Article Details

How to Cite
1.
Ghadeer FK, Alwan LE, Al-Azzawi AKJ. Crystallization firing effect on the marginal discrepancy of the IPS. emax CAD crowns using two different CAD/CAM systems. J Bagh Coll Dent [Internet]. 2023 Mar. 15 [cited 2024 Nov. 24];35(1):49-57. Available from: https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/3316
Section
Research Articles
Author Biographies

Fatima K Ghadeer , Middle Technical University (MTU), Collage of Health and Medical Techniques, Department of Prosthodontics Techniques, Baghdad , Iraq.

Middle Technical University (MTU), Collage of Health and Medical Techniques, Department of Prosthodontics Techniques, Baghdad , Iraq.

Lateef E Alwan , Middle Technical University (MTU), Institute of Medical Technology, Baghdad , Iraq.

Middle Technical University (MTU), Institute of Medical Technology, Baghdad , Iraq.

Abdul Kareem J Al-Azzawi, AL-Turath University, Collage of Dentistry , Baghdad , Iraq

AL-Turath University, Collage of Dentistry , Baghdad , Iraq

How to Cite

1.
Ghadeer FK, Alwan LE, Al-Azzawi AKJ. Crystallization firing effect on the marginal discrepancy of the IPS. emax CAD crowns using two different CAD/CAM systems. J Bagh Coll Dent [Internet]. 2023 Mar. 15 [cited 2024 Nov. 24];35(1):49-57. Available from: https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/3316

Publication Dates

References

Euán, R., Figueras‐Álvarez, O., Cabratosa‐Termes, J., et al Comparison of the marginal adaptation of zirconium dioxide crowns in preparations with two different finish lines. J Prosthodont Impl Esth Recon Dent. 2012; 21(4):291-5. DOI: https://doi.org/10.1111/j.1532-849X.2011.00831.x

Wolfart, S., Wegner, S.M., Al-Halabi, A., et al. Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation. Int J Prosthodont 2003; 16(6):51-55.

Gallucci, G.O., Guex, P., Vinci, D., et al. Achieving natural-looking morphology and surface textures in anterior ceramic fixed rehabilitations. Int J Perio Restor Dent 2007; 27(2):104-10.

Raigrodski, A.J. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004; 92(6):557-62. DOI: https://doi.org/10.1016/j.prosdent.2004.09.015

Shen, J.Z., Kosmač, T. Advanced Ceramics for Dentistry: Chapter 16. Advanced Dental-restoration Materials: Concepts for the Future: Elsevier Inc. Chapters; 2013. DOI: https://doi.org/10.1016/B978-0-12-394619-5.00016-X

Stappert, C.F., Att, W., Gerds, T., et al. Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation. JADA 2006; 137(4): 514-22. DOI: https://doi.org/10.14219/jada.archive.2006.0224

Dittmer, M.P., Borchers, L., Stiesch, M., et al. Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process. Acta Biomater. 2009; 5(8): 3231-9. DOI: https://doi.org/10.1016/j.actbio.2009.04.025

Holden, J.E., Goldstein, G.R., Hittelman, E.L., et al. Comparison of the marginal fit of pressable ceramic to metal ceramic restorations. J Prosthodont Imp Esthet Recon Dent. 2009; 18(8): 645-8. DOI: https://doi.org/10.1111/j.1532-849X.2009.00497.x

Holmes, J.R., Bayne, S.C., Holland, G.A., et al. Considerations in measurement of marginal fit. J Prosthet Dent 1989; 62(4): 405-8. DOI: https://doi.org/10.1016/0022-3913(89)90170-4

Bindl, A., Mörmann, W.H. Fit of all-ceramic posterior fixed partial denture frameworks in vitro. nt Int J Periodo Restor Dent 2007;27(6):403-8.

Tinschert. J., Natt, G., Hassenpflug, S., et al. Status of current CAD/CAM technology in dental medicine. Int J Comput Dent 2004; 7(1): 25-45.

Ritter, R.G. Multifunctional Uses of a Novel Ceramic‐Lithium Disilicate. J Esthet Restor Dent 2010; 22(5):332-41. DOI: https://doi.org/10.1111/j.1708-8240.2010.00362.x

Beyari, M.M. Marginal and internal crown fit evaluation of CAD/CAM versus press-laboratory all-ceramic crown. Clin Med Diagnos. 2014; 4(A): 21-6.

Akbar, J.H., Petrie, C.S., Walker, M.P., et al. Marginal adaptation of Cerec 3 CAD/CAM composite crowns using two different finish line preparation designs. J Prosthodont 15(3):155-63.. DOI: https://doi.org/10.1111/j.1532-849X.2006.00095.x

Hamza, T.A., Sherif, R.M. In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems. J Prosthet Dent 2017; 117(6): 762-6. DOI: https://doi.org/10.1016/j.prosdent.2016.09.011

Balkaya, M.C., Cinar, A., Pamuk, S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005; 93(4): 55-346. DOI: https://doi.org/10.1016/j.prosdent.2005.02.003

Dimashkieh, M. The Effect of Veneering Porcelain on the Marginal Fit of Cercon Zirconia Copings: Citeseer; 2010.

Al-Assadi, H.Z., Al-Azzawi, A.K.J. The effect of porcelain veneering on marginal fitness of zirconia copings compared to full contour zirconia crown using three different CAD/CAM systems (An In vitro study). J Gene Enviro Resources Conserv. 2015; 3(3): 205-11.

Ibraheem, A.F., Hmedat, S.J. A comparison of vertical marginal fit of three different types of all ceramic crown restorations (An In vitro study). J Gene Environ Resources Conserv. 2015; 3(1): 84-92.

Gonzalo, E., Suarez, M.J., Serrano, B., et al. Marginal fit of Zirconia posterior fixed partial dentures. Int J Prosthodont. 2008; 21(5): 761-6

Khdeir, R.M., Ibraheem, A.F. The Marginal Fitness of CAD/CAM All Ceramic Crowns Constructed by Two Typesof Direct Digitization Techniques (An In Vitro Study). J Bagh Coll Dentitsry 2016; 28(2): 30-3. DOI: https://doi.org/10.12816/0028210

Reich, S., Gozdowski, S., Trentzsch, L., et al. Marginal fit of heat-pressed vs CAD/CAM processed all-ceramic onlays using a milling unit prototype. Oper Dent 2008; 33(6): 644-50. DOI: https://doi.org/10.2341/07-162

van Steenberghe, D., Naertm, I., Andersson, M., et al. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants. 2002; 17(5): 622-9

Komine, F., Iwai, T., Kobayashi, K., et al. Marginal and internal adaptation of zirconium dioxide ceramic copings and crowns with different finish line designs. Dent Mater 2007; 26(5): 659-64. DOI: https://doi.org/10.4012/dmj.26.659

Vigolo, P., Fonzi, F. An In Vitro Evaluation of Fit of Zirconium‐Oxide‐Based Ceramic Four‐Unit Fixed Partial Dentures, Generated with Three Different CAD/CAM Systems, before and after Porcelain Firing Cycles and after Glaze Cycles. J Prosthodont. 2008; 17(8): 621-6. DOI: https://doi.org/10.1111/j.1532-849X.2008.00366.x

Kim, J-H., Oh, S., Uhm, S-H. Effect of the crystallization process on the marginal and internal gaps of lithium disilicate CAD/CAM crowns. Biomed Res Int. 2016; 20(16): 623-30. DOI: https://doi.org/10.1155/2016/8635483

Azarbal, A., Azarbal, M., Engelmeier, R.L., et al. Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials. J Prosthodont 2018; 27: 421-8. DOI: https://doi.org/10.1111/jopr.12683

Giordano, R. Materials for chairside CAD/CAM–produced restorations. JADA 2006; 137: 14S-21S DOI: https://doi.org/10.14219/jada.archive.2006.0397

Comlekoglu, M., Dundar, M., Özcan, M., et al. Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent. 2009; 34(5): 586-92. DOI: https://doi.org/10.2341/08-076-L

DeLong, R., Heinzen, M., Hodges, J., et al. Accuracy of a system for creating 3D computer models of dental arches. Dent Res J. 2003; 82(6): 438-42. DOI: https://doi.org/10.1177/154405910308200607

Beuer, F., Korczynski, N., Rezac, A., et al. Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts. Clin Cosm Investig Dent. 2010; 2:(5): 485-93. DOI: https://doi.org/10.2147/CCIDE.S6691

Bosch, G., Ender, A., Mehl, A. A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes. J Prosthet Dent. 2014; 112(6):1425-31. DOI: https://doi.org/10.1016/j.prosdent.2014.05.012

Neves, F.D., Prado, C.J., Prudente, M.S., et al. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent. 2014; 112(5): 1134-40. DOI: https://doi.org/10.1016/j.prosdent.2014.04.028

Similar Articles

You may also start an advanced similarity search for this article.